Description
Key Features
- High-rate pulse discharge capability
- Part of a range of compact sizes and capacities, from thin-type to high-capacity models
- Excellent low-temperature performance, enhanced by the manganese-dioxide positive pole
Used In
This is the correct replacement battery for:
- Safe-Life nurse call points
- Safe-Life In-Line Falls Prevention Monitor (SKU: A-SL-CON-M) — uses 2 × CR2477
Not sure which device you have? Check the battery compartment or the model sticker, or contact us on 03 9588 0392.
Specifications
| Property | Value |
|---|---|
| Nom. Volt. (V) | 3 |
| Nom. Cap. (mAh) | 1000 |
| Cont. Std. Drain (mA) | 0.2 |
| Diameter (mm, max) | 24.5 |
| Height (mm, max) | 7.7 |
| Weight (approx.) (g) | 10.5 |
| Oper. Temp. (°C) | -30 to 85 |
| Lithium content per cell (g) | 0.29 |
Terminal Options
Available with tabs or lead wires depending on configuration. See internal notes below before publishing — exact terminal codes for this SKU aren’t confirmed yet.
Shipping & Compliance (Australia)
At 0.29g of lithium metal per cell, the CR2477 sits well within the 1g per cell / 2g per battery threshold that governs how lithium metal batteries can be sent. It’s classified UN3090, Class 9, but qualifies for the Section II exemption (SP188 for marine, PI969/970 for air) because the lithium content is under 1g per cell and the cell type has passed the required UN Manual of Tests and Criteria (Part III, sub-section 38.3).
In practice, this means the cell can be sent within Australia, but loose cells (not installed in a device) can only travel by road, not air, and need to be packaged so terminals can’t short-circuit and clearly marked accordingly.
Safety Information
- Keep away from children. Swallowing a battery can cause serious internal chemical burns within as little as two hours.
- If swallowed, seek immediate medical attention. Contact the Australian Poisons Information Centre on 13 11 26.
- Do not recharge, short-circuit, disassemble, deform, or dispose of in fire. Do not heat above 100°C.
- Do not mix with other battery types, and don’t let terminals contact each other or other metal objects during storage or transport.