10 A Battery-Backed Power Supply for Nurse Call Displays

Run your annunciator displays and WAC-07 controller from one supply instead of a plug pack for each. If mains power fails, the fitted 7 Ah battery takes over and calls stay on the displays.


SKU: N-POWER-SUPPLY-10AMP

Description

What it is

A 10 A power supply with a backup battery, in a lockable metal case. We recommend it for any nurse call system with a WAC-07 Wireless Annunciator Controller and annunciator displays. One supply runs up to 4 single-sided or 3 double-sided displays, plus the controller, so you don’t need a plug pack for each display.

What’s included

  • 1 ร— 10 A power supply in a lockable metal case
  • 1 ร— 12 V 7 Ah sealed lead acid backup battery, fitted
  • Fused output for annunciator displays, fitted
  • 2 ร— keys
  • 1 ร— spare 10 A blade fuse

Features

  • Display output: 10 A for the displays, protected by an inline blade fuse and wired to lever terminal blocks.
  • 18 fused outputs for the WAC-07, RS485 splitter and data logger. Each output has a resettable fuse and an LED, so a fault on one device doesn’t take down the rest.
  • Battery backup: when mains power fails, the battery takes over. It recharges once power is back.
  • Lights on the door show Power, DC 12 V and Charge at a glance.
  • Two switches: one for mains power, one for the DC output.
  • Protection against short circuit, high voltage, over current and overheating.
  • Lockable metal case with room to tidy the cables.
  • BT STUP button to start the supply from the battery alone.

Connecting it

  1. Turn the power switch off.
  2. Connect the red and black leads to the battery: red to positive, black to negative.
  3. Connect the WAC-07 and other central equipment to the 550 mA outputs, one device per output. The top row is positive and the lower row is negative.
  4. Connect the annunciator displays to the display output terminal blocks: red is positive, black is negative.
  5. Plug the supply into a 240 V AC power point.
  6. Turn the power switch on. Each output LED and the battery charge LED should light.
  7. Close the cover and lock it with the key.

As the battery charges, the charge LED on the front panel gets brighter.

Specifications

Part number N-POWER-SUPPLY-10AMP
Model Securview PS12VDC10A18CHB
Input 100 to 240 V AC, auto switching
Output voltage 13.8 V DC
Total output current 10 A
Displays Up to 4 single-sided or 3 double-sided
Display output Inline blade fuse, lever terminal blocks
Equipment outputs 18, each 0.55 A with a resettable fuse and LED
Backup battery 12 V 7 Ah sealed lead acid (fitted)
Protection Short circuit, high voltage, over current, thermal cut-off
Case Metal, with key lock
Dimensions 265 ร— 205 ร— 90 mm
Use Indoor only
Warranty 12 months

Works with

Frequently asked questions

Do I need this, or will a plug pack do?

One display can run from the plug pack that comes with the display kit. Once you add a second display, it needs power too, and this supply covers up to 4 single-sided or 3 double-sided displays with battery backup.

How long will it run in a power failure?

That depends on how many displays you have. These are estimates, based on each device’s maximum current draw and the 7 Ah battery:

WAC-07 and 1 single-sided display about 5 hours
WAC-07 and 2 single-sided displays about 3 hours
WAC-07 and 4 single-sided displays about 1.5 hours
WAC-07 and 2 double-sided displays about 1.5 hours
WAC-07 and 3 double-sided displays about 1 hour

Real times vary with the battery’s condition and how many calls are on the displays.

How much does each device draw?

As a guide: a single-sided display about 1.1 A, a double-sided display about 2 A, the WAC-07 controller 200 mA, the RS485 splitter 200 mA and the data logger 360 mA. Send us your layout and we’ll check it for you.

Can I run display power in the data cable?

Yes, for single-sided and double-sided displays up to 80 to 100 m away, in the CAT5/6 cable. Further than that, voltage drop is too high, so the display needs its own power. You can also run power in separate figure 8 or security cable, at least 14/0.2 mm stranded. Any display powered separately must share a common ground with the rest of the system.

Why does a 12 V call point show “-LB-” on its first call?

Call points don’t usually run from this supply. If you do power a call point from 12 V, it shows “-LB-” (low battery) on its first transmission after it’s powered up. You can ignore it: it won’t appear on later calls.

How do I reset the system if a display freezes?

Open the case and flick the 12VDC Output ON/OFF switch off, then back on. Switching off at the power point won’t reset it, because the battery keeps the system running.

What about a small system with no displays?

If your call points send straight to pagers with no WAC-07, the PowerShield DC Mini UPS can back up each 12 V call point instead.

Can it be used outdoors?

No, it’s for indoor use only.

Is it GST-free?

It’s GST-free for eligible medical and disability use. Contact us for a quote.

Reviews

There are no reviews yet

Add a review
10 A Battery-Backed Power Supply for Nurse Call Displays 10 A Battery-Backed Power Supply for Nurse Call Displays
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
Add photos or video to your review


Add a review

10 A Battery-Backed Power Supply for Nurse Call Displays
10 A Battery-Backed Power Supply for Nurse Call Displays
Rating*





0/5

* Rating is required


Your review

* Review is required

Name

* Name is required




Add photos or video to your review



0.0
Based on 0 reviews
5
0%
4
0%
3
0%
2
0%
1
0%
0 of 0 reviews

Sorry, no reviews match your current selections

Enquiry Cart
Enquiry Cart ×
Loading....